Open one formal result you may need to rely on. Write the behavior it claims and one consequential assumption. Then locate evidence that your implementation establishes that assumption, or mark the relationship unknown. The free human record keeps that gap beside the decision it could affect. The worked exercise concerns a control function that wants recent sensor samples. Its mathematical model subtracts the stored sample timestamp from the current timestamp. The chosen local rule accepts ages from zero through nineteen milliseconds. Timestamp inputs are nonnegative, unbounded integers. This teaching rule is not an aviation requirement. The original guard checks only that age is below twenty. Assuming the sample timestamp is no greater than the current timestamp makes its local range claim hold. Remove that ordering and deliberately choose current ten, sample one hundred: age is negative ninety. The recorded model checks confirm acceptance, contrary to the local rule. The revised model adds the missing lower bound. Its local range check succeeds directly because acceptance uses that same range. A chosen current timestamp of one hundred five and sample timestamp of one hundred still gives five milliseconds and is accepted. These are model observations; no implementation was repaired. A positive difference can still mislead. The separate elapsed rule also requires zero through nineteen milliseconds. Using common units and no wrap, authored one-reset arithmetic uses old sample five, reset to zero at old tick one hundred, and new current ten. Apparent age five is accepted; modeled elapsed age one hundred five fails freshness. No physical reset transition was executed. Retain the local conclusion and record what it cannot establish about real freshness. Ask your project lead to appoint an implementation owner and a reliance decision authority. Inspect the actual timestamp path and agree the next observation. That implementation work is unperformed here, and no project approval is recorded.