  "kind": "fictional nonclinical teaching contract; not a medical-device specification",
  "authority": "Fictional fixture owner, created for this example; no real quality or regulatory approval",
  "revision": 1,
  "unit_definition": "4 integer ticks = 1 arbitrary display unit u; no clinical/physical unit or patient value",
  "requirements": [
    {
      "id": "DISP-01",
      "text": "An available reading must be an exact integer from 0 through 40 inclusive. Convert by division by 4 and display one decimal place, rounding an exact nonnegative halfway value upward to the next tenth."
    },
    {
      "id": "DISP-02",
      "text": "None means unavailable. Return state unavailable, text Unavailable and unit null. Do not display numeric zero."
    },
    {
      "id": "DISP-03",
      "text": "Reject booleans, strings, floats and other noninteger inputs as TYPE. Reject integer values below 0 or above 40 as RANGE. No negative input is rounded, including any would-be negative tie."
    },
    {
      "id": "DISP-04",
      "text": "Valid converted values use state value and unit u. Invalid inputs use state invalid, text Invalid input, no unit and the specified reason."
    }
  ],
  "rounding_scope": "All accepted values are nonnegative. Half-up means advance an exact halfway value to the next tenth; negative values are invalid rather than subject to a negative rounding policy.",
  "exclusions": [
    "No actual medical device or clinical values",
    "No hardware/UI/locale rendering, timing, concurrent data or stale-reading semantics",
    "No risk assessment, software safety class, FDA Documentation Level, standard conformity or release acceptance"
  ]
}